Could this have caused a melted fusebox? 700 1986

In a word...No.
The distributor is not connected to the fusebox.
Fuse socket melted either because there there was close to 25 amps flowing through it for quite awhile (and Volvo used the wrong plastic) or most likely, there is a corroded contact in that area (fuse to receptacle, wire to receptacle) and heat was generated by the poor connection (resitance).


--
84 242Ti IPD bars&springs, 89 745 16v M46 IPD bars, 89 744 16v M46 IPD bars, 93 945 Turbo AW71, 91 245SE AW70 IPD bars, 93 245 CLassic M47






THREADED THREADED EXPANDED FLAT PRINT ALL
MESSAGES IN THIS THREAD

New Could this have caused a melted fusebox? [700][1986]
posted by  alschnertz subscriber  on Sat Aug 1 05:55 CST 2009 >


<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.