Thank you everyone for the tips. I just did the voltage check at the o2 sensor and got rapid movement between 2.5 and 6.5 volts. Then I followed the test proceedure suggested by Bruce Young. I got slow movement between .5 and .6 volts closed loop. Then I unplugged the ecu wire and and did a full rich test. the o2 signal was a steady 1.1 and I applied the 1.5v battery to the green ecu wire and absolutly nothing happened. I then did the full lean test, grounding the green wire and again absolutly nothing happened and the o2 volts remained at 1.1 I put everything back together and tested the voltage again at the o2 sensor and got a fluctuating reading of .5 to .6volts.
I'm confused about getting what seemed like normal readings at first and than not being able to duplicate those readings. Any suggestions?
|