Re: Fuse holder #6 melting 200 1991

Steve -- about 18 months ago I was having a similar problem with the fuel pump fuse holder on my '81 245. I checked the amp draw of the fuel pump and it was right in spec. I was told by several posters that where the resistance was highest (i.e., the fuse holder) is where the problem lay. So...I went to my local pick-n-pull and snagged two good looking fuse panels. I took the cleaner one and cleaned it some more, pinched the clips tight and replaced my melted one. I haven't had a problem with warm fuses or wires ever since.

Rob






THREADED THREADED EXPANDED FLAT PRINT ALL
MESSAGES IN THIS THREAD

New Fuse holder #6 melting [200][1991]
posted by  someone claiming to be Steven Manseau  on Tue Nov 21 05:24 CST 2000 >


<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.