A temporary (?) OD relay bypass 200 1993

When you've found the OD relay, per Art's directions, you can do a temporary* diagnostic bypass with a jumper wire at the relay harness connector plug.
Just connect these two plug terminals together with a "jumper" wire:
• Input terminal #15 (2 wires, a Blue-Black and a Gray)
• Output terminal #87 (1 White wire)

A good-fitting jumper can be made with flat male crimp-on terminals that are the similar to the relay terminals. This jumper wire will simulate a relay that is always energized — which is the normal condition, until the shifter button is pressed.

* If the OD works OK with the bypass jumper (and you don't need the shifter button downshift option), you can just leave the jumper wire in place.

--
Bruce Young, '93 940-NA (current), 240s (one V8), 140s, 122s, since '63.






THREADED THREADED EXPANDED FLAT PRINT ALL
MESSAGES IN THIS THREAD

New 240 overdrive [1993]
posted by  whtzin  on Mon Nov 9 12:16 CST 2009 >


<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.