testing hall sensor, faq describes "Undo dist. conn.' is that the three wire signal sensor? 700

under the cap of distributor, the three wire, blk, blue, red these described leads should show described figures
or am i missing something

Undo the distributor connector. When the ignition is ON the Voltage between positive terminal (red lead -Nr. 3) and ground should be approx. 11V. Voltage between (blue lead - Nr.2; middle one) and ground should be 5V although if you put it on a scope you would see the sharp rise and fall from 12v to ground as the distributor rotates. Pulse frequency varies as rpm is increased. . Resistance between (black lead - Nr. 1) and ground should be close to zero Ohms. Undo connector from the control unit (above the brake pedal) and remove the sealing washers (plastic inserts on the side of the connector). Replace connector without cover or sealing washers.
- Disconnect the/red and blue leads from ignition coil. - Measure voltage between terminal 24 at rear of control unit connector (blue lead) and ground. NOTE: Connector must be attached to control unit. Switch on ignition. Turn crankshaft by hand. Voltage should indicate OVER 1.8V each time a vane passes Hall generator. Instrument should read approx."0" (0 - 0.7V) each time an opening passes Hall generator. The correct voltage is less than 0.7V or more than 1.8V.








<< < > >>



©Jarrod Stenberg 1997-2022. All material except where indicated.


All participants agree to these terms.

Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.