1800ES owners input wanted (technical)[850/1995] posted by Robert van Dam on
Thursday, 19 March 1998, at 8:05 p.m.
Just be accident I noticed that the power consumption with the ignition switch in the
Re: 1800ES owners input wanted (technical)[850/1995] posted by Thilo on
Friday, 20 March 1998, at 9:03 a.m.
Robert,
I wonder whether your fuel pump is running when the ignition is "ON".
On my P1800E the pump is running all the time, but on my 1800ES it is only running when the starter or the engine is running.
Small amount of power consumption is caused by the ECU itself, the gauges for water and oil temperature as well the fuel gauge.
The home of the classic sports car long distance rallye
Re: 1800ES owners input wanted (technical)[850/1995] posted by Jim McDonald on
Friday, 20 March 1998, at 10:58 a.m.
The ignition coil by itself should pull 4.5-5A.
Re: 1800ES owners input wanted (technical)[850/1995] posted by Robert van Dam on
Saturday, 21 March 1998, at 9:03 a.m.
They way I do this test is as follows. The neg terminal of the battery is disconnected while the ignition key is on.
I make a connection through the amp-meter (Fluke) between the ground strap and the battery terminal. The fuel pump runs for a short while after the FI-relay kick in, at that moment I read 4 Amps.
Can you measure what this reading is on your car so I car if mine is right?
Robert
Re: 1800ES owners input wanted (technical)[850/1995] posted by Ed Lipe on
Saturday, 21 March 1998, at 9:21 a.m.
Unless your fluke is specifically reading DC amps, You're not getting a real reading. Even Amprobe makes two different meters for AC and DC. An inexpensive meter like a dash guage or one found on a battery charger will give you a fair reading. ED7
Re: 1800ES owners input wanted (technical)[850/1995] posted by Ed Lipe on
Saturday, 21 March 1998, at 9:29 a.m.
If you are, in fact, reading dc amps; Start pulling fuses one at a time to determine the area to look at for the draw. ED7
Re: 1800ES owners input wanted (technical)[850/1995] posted by Mike on
Wednesday, 25 March 1998, at 3:21 p.m.
The instruments of course are drawing current, but Jim is probably closer. Remember that with breaker point ignition (not "electronic") as on the ES, whenever the points are closed, they connect the coil to ground (Battery neg.) which completes the primary ignition circuit. The other side of the coil is connected to +12V (Battery pos) via the ignition switch. When your engine is not running, the points may be open or closed, depending on the rest position of the engine. You should be able to feel the coil heat up after a few minutes if the ignition is on and the points closed. To test, while the meter is indicating 4 A current draw, pull the primary wire (not the high tension wire to the cap) from the side of the distributor or coil. If the points are closed, the current should drop significantly. Isolate the wire end and turn off the ignition before reconnecting the wire to prevent sparking.