'84 DL wagon heater fan stopped running[ALL/1988] posted by Ken on
Saturday, 7 February 1998, at 8:04 p.m.

Before I replace the fan, is there something else I should check
that may have caused it to stop abruptly? One day it was working
fine, the next day, nothing. The fuse is OK and the other things
on the circuit work fine.


Re: '84 DL wagon heater fan stopped running[ALL/1988] posted by Ted Y. on
Saturday, 7 February 1998, at 11:33 p.m.

I hope there is something else. or else.... good luck!
I replaced the blower motor im my mom's 1977 245. My boss, when I worked in an independent Volvo/Saab garage, told me the bushings were probably shot in mine. I paid $80 for an upgraded (4speed) fan, and got to work.

The job was definitely not one of the EASIEST things I have ever done. It took me a good 8-10 hrs., since this was my first time doing this. Also, since I was not using a 1977-style fan, some modifications were neccesary to the cowling? surrounding it. The new fan was larger than the old one.

One thing I DO reccomend, (I don't know your experience level, but mine is not at the professional level) is to put one peice of tape on each of the many, many, wires you will wind up disconnecting. On the tape, you should number, color, etc.. the wire as to avoid future confusion when re-assembling everything. The job itself is not extremely difficult, but it is extremely labor-intensive (in my opinion.).

One thing I can say, however, is that my mom's heater kicks BUTT now. On setting #1, the passenger area gets hot. On setting #2, it becomes UNCOMFORTABLY hot. #3 is for arctic temperatures, and on fan speed #4, you could MELT PLASTIC!

Good luck, I hope your problem is not related to the fan.

Ted Y.


Re: '84 DL wagon heater fan stopped running[ALL/1988] posted by Henry T. Mui on
Tuesday, 10 February 1998, at 4:05 p.m.

Ken,
may I suggest that you a rebult heater motor that has the steel bushings in the motor removed and replaced with ball bearing or the broze oil lite bushings, depending on the model. This ensures that the motor will not be replace for a long time. Cost is @$85-$95. Plus old motor core, plus shipping charges:

Contact Bill Cheb.

9828 79 th. Street.

Edmonton, Alberta.

Canada, T6A-3G1.
Phone: 403-465-4960.

Good luck, them things are a real pain to get out and put back it!




 


©Jarrod Stenberg 1997-2020. All material except where indicated.



Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.