Re: Turbo Warmup/Cooldown:Waste of Time?[ALL/1998] posted by Ed Lipe on
Sunday, 26 April 1998, at 3:18 p.m.
Another alternative to a turbo timer, is a prelube pump as is used on industrial engines.
This is a simple hydraulic pump that puts oil pressure to all bearings in the engine, including the turbo, prior to start-up. It is normally run for a minute, or long enough to see pressure indicate on the guage and turns off after starting the engine. The prelube pump could easily be timed out after shutting down the engine with a time delay relay or 240 style defroster switch. The oil flow afterward would help cool things off after shut down as well as good protection prior to start-up. Also a lot cheaper than a turbo timer.
There is no substitute for adequate warm-up or cool-down of an engine. The turbo is not the only thing you should be concerned about.
ED7, '51 R25, '65 R69S, '67 1600 GT, '86 745 TD, '90 240 GL, '95 RWL