My volvo S70 compressor does not run and I have tested and eliminated all causes except the linear pressure switch (High Pressure switch)! It has the automaticc climate control system.
1. The compressor runs if I bypass the AC relay
2. The pressostat works fine (I tested it)(tested with ohmmeter as well as bypaassed to test)
3. The low side pressure is fine (Tested with AC pressure guage)
4. The AC switch sends +12V to the ECM via the pressostat (Tested!)
5. Tested the AC relay (Works fine)
6. The ECM is supposed to activate the relay under these conditions by grounding the low side of the relay. It does not ! (It is around 11.5 V)
7. The Linear pressure switch (actually sensor) is putting out only 0.11V, with or without the compressor being turned on. So I suspect it is not functional!
8. Does anybody know what voltage is expected out of the linear pressure sensor for the ECM to be happy and turn on the AC compressor? Is there a better way to test it other than spend a $100 and get a new sensor!
Any information from the AC experts would be appreciated. It is getting warmer here in NJ and soon it would be impossible to drive without AC!!
Thank You
Ramesh52
|
|
[about brickboard ads]
|
Volvo S70 AC High Pressure Switch
posted by
ramesh52
on Fri May 9 19:00 CST 2008 >
V
-
Volvo S70 AC High Pressure Switch
posted by
TomL
on Sat May 10 13:54 CST 2008 >
V
Users marked in green are currently online.
©Jarrod Stenberg 1997-2007. All material except where indicated.
Brickboard.com is not affiliated with nor sponsored by AB Volvo, Volvo Car Corporation, Volvo Cars of North America, Inc. or Ford Motor Company. Brickboard.com is a Volvo owner/enthusiast site, similar to a club, and does not intend to pose as an official Volvo site. The official Volvo site can be found here.